West-control-solutions KS 800 Operating Instructions Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek West-control-solutions KS 800 Operating Instructions. West Control Solutions KS 800 Operating Instructions User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2

Multi-Temperature-Controller KS 800For units with analog outputs,2 x 8-pole terminal, order no. 231-308/026-000, resp. 9463 000 05321 is required addi

Strona 3

Multi-Temperature-Controller KS 8004.3 Galvanic isolationsThe galvanic isolations of KS 800 are shown in the following diagram.Identical block shading

Strona 4

Multi-Temperature-Controller KS 8004.4 Supply voltageKS 800 is designed for a supply voltage rating of 24V DC, range 18V to 30V, residual ripple 5%.Th

Strona 5 - 1 Safety hints

Multi-Temperature-Controller KS 8005 Inputs(A complete KS 800 connecting diagram is given in section 7.)Examples for connection are given in section 5

Strona 6 - 2 General

Multi-Temperature-Controller KS 800The controller inputs are not galvanically isolated. Therefore, measurement errors may occur withthermocouple measu

Strona 7 - 3 Installation

Multi-Temperature-Controller KS 8005.3 Resistance thermometer (IN1+/IN1-/IPT1 ... IN8+/IN8-/IPT8)Pt 100, 2 or 3-wire connectionResistance thermometer

Strona 8

Multi-Temperature-Controller KS 800The current transformer input is not a measurement input in the sense of a calibrated measuringinstrument. The soft

Strona 9 - 4 Electrical connection

Multi-Temperature-Controller KS 8005.6 Input circuit examples5.7 Digital inputsKS 800 contains 4 digital inputs, which can also be configured individu

Strona 10

Multi-Temperature-Controller KS 8005.8 Input/output forcingUnless connections IN/OUT13...IN/OUT16 or OUT17...OUT19 are used for their actual tasks, th

Strona 11

Multi-Temperature-Controller KS 8006 Outputs(For the complete connecting diagram, see section 7.2, 7.3)6.1 Controller outputs:Dependent of controller

Strona 12

©PMA Prozeß- und Maschinen-Automation GmbH 2004. Printed in GermanyAll rights reserved. No part of this document may bereproduced or published in any

Strona 13 - 5 Inputs

Multi-Temperature-Controller KS 800OUT17...OUT19 3 outputs for alarms. The alarm allocation to the three outputs is confi-gurable.Unused outputs canno

Strona 14

Multi-Temperature-Controller KS 800Starting with controller 1, the 1st controller, which has a continuous output, is allocated to analogoutput 1 (AO1)

Strona 15

Multi-Temperature-Controller KS 800Note: Unless these alarm outputs are used as alarm outputs, they can also be used as digitaloutputs of a control sy

Strona 16

Multi-Temperature-Controller KS 8007 Circuit diagrams7.1 Input/output circuit diagramFor better understanding with complex connecting problems, the ci

Strona 17 - See also hint on page 21

Multi-Temperature-Controller KS 8007.2 KS 800 overall connecting diagram with/without continious outputs24 9499 040 49111

Strona 18

Multi-Temperature-Controller KS 8007.3 KS 800 overall connecting diagram with constant voltage 10V9499 040 49111 25

Strona 19 - 6 Outputs

Multi-Temperature-Controller KS 8008 Digital interfacesCommunication with controller KS 800 is possible only via the digital interfaces. Reading proce

Strona 20

Multi-Temperature-Controller KS 8008.2.2 DeviceNet adaptorIf KS 800 is operated with DeviceNet, an adapter is required for this bus system. This adapt

Strona 21

Multi-Temperature-Controller KS 8008.2.3 COM2 interfaceAddress and Baudrate for the COM2 interface can be adjusted via hardware or software for eachKS

Strona 22

Multi-Temperature-Controller KS 8008.3 Terminating resistorsHints related to baudrates, bus lengths, properties of electrical cables and mutual effect

Strona 23 - 7 Circuit diagrams

Multi-Temperature-Controller KS 800Contents1 Safety hints ... 51.1 Electromagnetic compatibility .

Strona 24 - 24 9499 040 49111

Multi-Temperature-Controller KS 800LED on: O.K., cyclic data exchange busyLED blinks: (2 Hz) data communication interruptedLED blinks: (4 Hz) PROFIBUS

Strona 25 - 9499 040 49111 25

Multi-Temperature-Controller KS 80010 Maintenance and measures in case of troubleThe KS 800 multiple controller needs no particular maintenance. There

Strona 30

Subjekt to alteration without notice.Printed in Germany 9499 040 49111 (022004)© PMA Prozeß- und Maschinen-Automation GmbHP.O.B. 31 02 29, D - 34058 K

Strona 31 - WARNING! WARNING!

Multi-Temperature-Controller KS 8009 Indicator LEDs ... 279.1 Outputs ...

Strona 32

Multi-Temperature-Controller KS 8001 Safety hintsFollowing the enclosed safety hints 9499 047 07101 is indispensable!For hints on the power supply to

Strona 33

Multi-Temperature-Controller KS 8002 GeneralKS 800 is a microcomputer-based multi-loop temperature controller. Functions "set-point lowering"

Strona 34

Multi-Temperature-Controller KS 8002.1.1 Possible output configurationsProvided that other criteria are taken into account, the following controller c

Strona 35

Multi-Temperature-Controller KS 800Several units: For mounting several units side by side, snap on the first unit to the rail and lockonly the side on

Strona 36

Multi-Temperature-Controller KS 8004 Electrical connection• Measurement and signal leads may carry max. 50 V rms against earth.• Mains cables must be

Komentarze do niniejszej Instrukcji

Brak uwag